Parameter | Description |
---|---|
Name | Name of the unit. |
Description | Description of the unit. |
Template name | Name of the unit type template |
Template version | Version of the unit type template |
Timeout between keystrokes | Max time between keystrokes before terminal goes back to default state (seconds). |
LCD refresh time | Timeout between automatic refresh of information in the KT LCD (seconds). Set to 0 to not refresh at all. |
24 Hour clock | If this check box is checked, the time should be displayed with a 24 hour clock. If it is not checked, it should be displayed with a 12 hour clock. |
Min time between call next | Defines the time that must elapse between two call next on a Service Point for a specific user (seconds). |
Parameter | Description |
---|---|
Name | Name of the unit. |
Description | Description of the unit. |
Type name | Name of the unit type. |
Type description | Description of the unit type. |
Unit id | Identification code of the unit. |
Store next | If enabled, the next customer will be called automatically (according to the set work profile) |
LED show when calling | From the drop-down list, select what to show on the LED display when calling a visit. |
LED Open text | Text on LED display when Service Point is open but not serving any visit. Leave empty if not used. |
LED Open scroll direction | Select the wanted scrolling direction for LED Open text, from the drop-down list. |
LED Open scroll speed | Select the wanted scroll speed for LED Open text, from the drop-down list. |
LED Waiting text | Text on LED display when Service Point is waiting for a visit (in Store next mode). Leave empty if not used. |
LED Waiting scroll direction | Select the wanted scrolling direction for LED Waiting text, from the drop-down list. |
LED Waiting scroll speed | Select the wanted scroll speed for LED Waiting text, from the drop-down list. |
LED Closed text | Text on LED display when Service Point is closed. Leave empty if not used. |
LED Closed scroll direction | Select the wanted scrolling direction for LED Closed text, from the drop-down list. |
LED Closed scroll speed | Select the wanted scroll speed for LED Closed text, from the drop-down list. |
P1 behavior | Behavior of button P1. Available choices are: User defined work profile, Locked to work profile 1, Locked to profile 2, Locked to profile 3, Locked to profile 4, or Locked to profile 5. |
P2 behavior | Behavior of button P2. Available choices are: User defined work profile, Locked to work profile 1, Locked to profile 2, Locked to profile 3, Locked to profile 4, or Locked to profile 5. |
P3 behavior | Behavior of button P3. Available choices are: User defined work profile, Locked to work profile 1, Locked to profile 2, Locked to profile 3, Locked to profile 4, or Locked to profile 5. |
P4 behavior | Behavior of button P4. Available choices are: User defined work profile, Locked to work profile 1, Locked to profile 2, Locked to profile 3, Locked to profile 4, or Locked to profile 5. |
P5 behavior | Behavior of button P5. Available choices are: User defined work profile, Locked to work profile 1, Locked to profile 2, Locked to profile 3, Locked to profile 4, or Locked to profile 5. |
Green LED | Select the wanted behavior of the green LED, from the drop-down list. |
Red LED | Select the wanted behavior of the red LED, from the drop-down list. |
Use login | Check this check box if you want to log in before using the terminal. |
Logout on close | Automatically log out when closing Service Point |
LED flash time | LED Display flash time (seconds). |
LED turn off time | Automatically turn off Service Point display after this time of inactivity (seconds). |
Auto close | Automatically close Service Point after this time of inactivity (seconds). |
Device Controller | From the drop-down list, select which default Device Controller should be used. |
Parameter | Description |
---|---|
Default name | Default name of the unit. |
Description | Description of the unit. |
Number of units (max 127) | Enter the number of units to create when publishing this unit to a configuration. |
Unit Identifiers | A table with unit identifiers, which is dependant on which Number of units you have entered in the field above. So, if the number 4, for example is entered, the table will automatically get 4 rows. The two columns of the table are: • Name - Name of the unit, by default the name of the unit plus a sequential number, for example WebReception 5 or WebServicePoint 2. Can be changed to anything, so long as the name is unique, within the Branch. • Logic Id - An ID used in the connectors. The Logic Id continues with the next number in the sequence of the auto generated ID's within the unit type (e.g. Service Points, Entry Points, or Presentation Points). The number can be changed to anything, in the range of 1-9999, as long as it is unique within the Service Point, Entry Point, or Presentation Point. Example: If you have a total of 4 units and let the first three keep the automatically set Logic Id’s 1-3, then manually set the fourth unit to Logic Id 12, then change the Number of units to 5, the fifth unit will automatically get Logic Id 4. |
Unit id | Identification code of the unit. |
ID Code | ID code. Valid values between 1-125. |
Device Controller | Name of Device Controller that is used. |